schneider-electric interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
1000
VMScore
CVE-2013-0657
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and previous versions allows remote malicious users to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
Schneider-electric Interactive Graphical Scada System
Schneider-electric Interactive Graphical Scada System 9.0
2 EDB exploits
NA
CVE-2022-32522
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS D...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32523
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGS...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32524
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSd...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32525
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServ...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32526
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataS...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32527
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSda...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32528
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affecte...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32529
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSda...
Schneider-electric Interactive Graphical Scada System
828
VMScore
CVE-2021-22710
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) ...
Schneider-electric Interactive Graphical Scada System
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
encryption
CVE-2024-4331
CVE-2024-26925
arbitrary code
CVE-2006-4304
CVE-2024-25458
CVE-2024-27077
reflected XSS
CVE-2024-4059
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
5
6
NEXT »